Buy printers, storage solutions and other tools online and get fast, free delivery. A liquid is identified as an ignitable hazardous waste if it is a solid waste and a representative sample of the waste has the following properties. The most commonlyused open cup method is known as the cleveland open cup coc. Slow speed gear motor with twin pulley rotates stirrer of penskymartens closed cup flash tester at 115 rpm for the basic procedure or at 250 rpm for suspensions of solids and highly viscous samples.
Astmd93 standard test methods for flash point by penskymartens closed cup tester astmd93 2019 edition current show complete document history how to order. Penskymartens closed cup flash tester flash point testing. On this method a sample is heated at a constant rate and a test flame is applied at regular intervals. Slow speed gear motor rotates stirrer of penskymartens tester at 105rpm for procedure a and at 250rpm for procedure b. Aircooled model abl8a and liquid cooled model abl8lare available for different temperature ranges. The main advantage of the closed cup flash point tester is the equilibrium between the liquid sample and the vapor above the liquid sample inside the brass cup established by the lid resulting in a closed environment inside the brass cup which best indicates the lower flammable limit of a sample during the sample test ideal to determine and to. Flashpoint penskymartens test equipmentflashpoint tester pma 4. Penskymartens closedcup flash point tester purpose and scope the instrument is designed and made as per the national standard of peoples republic of china gbt2612008 test methods for flash point of petroleum products penskymartens closed cup methods. It is protected by two 16 a slowblow primary fuses, one for the live conductor and one for the neutral conductor. The heating bath can be controlled to give a temperature rise of 5 to 6cmin. Singlesource gas supply design for cleveland flash and fire point testing.
Nf m07019, flash point by penskymartens closed tester. Penskymartens closed cup flash tester electrically heated 220240v, 5060 hz. Astmd93 standard test methods for flash point by pensky. Determines flash and fire points with a 1250w nickelchromium heater. Koehler k16010 cover assembly for pensky martens closed cup flash point tester. Testing conducted on a owc mercury accelsior pro q pcie ssd with 1. For flash and fire points of all petroleum 17 products, except fuel oils and those having an open cup flash below9c75f. Manufacturers and suppliers of flash point testing equipment.
Automatic cleveland and penskymartens flash point tester. A number in parentheses indicates the year of last reapproval. Code part name remarks apm00015 apm8 penskymartens closed cup flash point tester code part name qty remarks apm02001 test cup assembly 1 32000035 thermofuse 1 pack of 5, with insulation tube. Tester conforms to astm d92 and related specifications. Purpose and scope the instrument is designed and made as per the national standard of peoples republic of china gbt2612008 test methods for flash point of petroleum products penskymartens closed cup methods. The mac iii performance features an autosensing switchmode power supply that automatically adapts to 200240 v nominal ac power at 50 or 60 hz. Penskymartens closed cup flash tester, electrically heated 115v 5060 hz. Flash point determination instrumentation flash point testing equipment koehler instrument company inc is a manufacturer of penskymartens closedcup testers, penskymartens opencup testers, cleveland opencup tester, rapid flash tester closedcup, and autoignition apparatus. With over 40 years of experience, mac performance knows how to provide the parts and customer service you need and expect from a performance company. Again, as the name suggests, the flash point in the closed cup method is conducted inside a. Penskymartens closed cup flash tester, gas heated model list pricequantity total. Kinematic viscosity is of primary importance in the design and selection of a wide range of petroleum products.
Pensky martens closed cup flash tester electrically heated 220240v, 5060 hz. Automatic penskymartens closed cup flash point tester koehler. Slow speed gear motor rotates stirrer of pensky martens tester at 115rpm for procedure a and at 250rpm for procedure b. Koehler k16203 penskymartens closed cup flash point. Three test procedures are built in for varied samples. Product description the koehler k902 is for flash and fire points of all petroleum products, except fuel oils and those having an open cup flash below 79c 175f. The system software runs on an integrated processor pc running the latest windows operating system. Determines flash and fire points by the cleveland open cup method.
Pensky martens closed cup flash tester, gas heated model list pricequantity total. Chuck accepts flexible stirrer shaft of flash tester. Benchmark testing conducted in march 2017 using a 2. Model apm8 is an automated penskymartens closed cup flash point tester. What test methods are approved for determining if a liquid. Apm00015 apm8 penskymartens closed cup flash point. Through partnerships, cannon is proud to offer several types of automated flash point testers to suit a variety of testing needs. For determination of flash points up to 230f 110c h2085.
Petrotest germany, a company of anton paar, now offers the pma 5 penskymartens astm d93 flash point tester that performs flash point testing of petroleum products using penskymartens closedcup astm d93 a, b and. A wide variety of pour point tester price options are available to you, such as usage, power. Large screen lcd display in chinese measuring range. Koehler k16010 cover assembly for penskymartens closed cup flash point tester. Automatic penskymartens flash point tester with integrated fire extinguisher request information. The penskymartens flash point tester consists of a closedcup test arrangement that contains any vapors produced and essentially simulates the situation in. Koehler k16203 penskymartens closed cup flash point tester, 115v60hzce. Open and closed cup flash point what is the difference. Model abl8 is an automated abel closed cup flash point tester to cover flammable and combustible materials for shipping and safety regulations. Pma 5 is suitable for flammability applications on both biodiesel and biodieselblended fuels along with distillate fuels like diesel, heating oil, and kerosene.
Heating cooling is by energy efficient peltier modules attached to a metal block bath. The flash point here will vary according to the distance between the substance and the ignition source the height of the source above the cup. Astm d93, iso 2719, ip 34 cleveland open cup flash and fire point tester. Apm7 automated penskymartens closed cup flash point.
The apm7 automates the penskymartens closed cup pmcc flash point test. K16225 stirrer motor, 115230v 5060hz slow speed gear motor rotates stirrer of pensky martens tester at 105rpm for procedure a and at 250rpm for procedure b. Automatic penskymartens closed cup flash point analyzer 110240v 5060hz koehler k7. Determines flash and fire points by the cleveland opencup method. Pensky martens closed cup flash tester, electrically heated 115v 5060 hz. Flash point testers list of new and used for sale labequip. Koehler k16010 cover assembly for penskymartens closed. Automated penskymartens closed cup flash point tester. Determines flash points of a wide range of products by a closed cup method with two option speed stirring of the sample. The main advantage of the closedcup flashpoint tester is the equilibrium between the liquid sample and the vapor above the liquid sample inside the brass cup established by the lid resulting in a closed environment inside the brass cup which best indicates the lower flammable limit of a sample during the sample test ideal to determine and to. Koehler k16203 pensky martens closed cup flash point tester, 115v60hzce. Flashpoint with closed cup penskymartens method pma 4. In accordance to astm d93 procedure a, b and c stirring rate.
Mac performance is the leader in automotive and motor cycle performance parts and accessories. Download the free speedtest macos app today for the quickest way to check your connectivity. The automatic cleveland opencup coc measures and describes the properties of a sample in response to heat and a test flame under controlled conditions. Hk261b automatic cleveland open cup and pensky martens closed cup flash point tester confirms to the astm d92 standard test method for flash and fire points by cleveland open cup tester and astm d93 standard test methods for flash point by pensky martens closed cup tester, is used for open and closed cup flash point of petroleum products. Astm d93 flash point tests by penskymartens closed cup. Semi automatic pensky martens flash point tester, housed in a cast aluminium case, incorporating conectors for electricity, gas and cooling water. Petrotest germany, a company of anton paar, now offers the pma 5 pensky martens astm d93 flash point tester that performs flash point testing of petroleum products using pensky martens closed cup astm d93 a, b and c methods. Flash printers point of sale mac accessories apple. Theres nothing faster than launching a speedtest straight from your mac toolbar. Basics of penskymartens closedcup flash point testing anton. The automated penskymartens flash point analyzer represents a perfect union of nextgeneration technology with traditional robust quality. Flash point pensky martens test equipment flash point tester pma 4. Manufacturers and suppliers of flash point testing. Stirrer motor for pensky martens closed tester 115230v, 5060 hz.
The seta pm93 is a fully automated pensky martens closed cup flash point tester which combines strict method conformance with the latest control technology and safety systems to provide the ultimate level of fast, accurate and safe analysis. Astm d92, iso 2592, jis k22654, ip 36, aashto t48, ftm 7911103, gost 4333 the best flash point tester for every task. Precision melting point tester contact us we would like to hear from you get information now on products, technical support, customer service, sales, public relations, professional services, and partners. The apm7 automates the pensky martens closed cup pmcc flash point test. This will be detected and signaled, preventing an accident or damage. Our automated flash point testers include the abel closed cup, tag closed cup, pensky martens closed cup, cleveland open cup and sixposition cleveland open cup flash point testers. Apm00015 apm8 penskymartens closed cup flash point tester code part name qty remarks apm02001 test cup assembly 1 32000035 thermofuse 1 pack of 5, with insulation tube. Standard test methods for flash point by penskymartens closed cup tester1 this standard is issued under the. Procedurea for homogeneous petroleum liquids such as distillate fuels, procedureb for residual fuel oils and some other nonhomogeneous liquids, and procedurec for biodiesel.
The cup cover and stirrer are installed on a swing arm assembly for easy onehand setup. For flash point determinations of fuels, lubricating oils, liquids containing suspended solids and liquids that tend to form a surface film during testing. Automated penskymartens closed cup flash point tester apm. Flash point is the lowest temperature, corrected by barometric pressure, at which application of ignition source causes vapors of sample to. Quick cooling is facilitated by a high velocity fan. Hk261b automatic cleveland open cup and penskymartens closed cup flash point tester confirms to the astm d92 standard test method for flash and fire points by cleveland open cup tester and astm d93 standard test methods for flash point by penskymartens closed cup tester, is used for open and closed cup flash point of petroleum products. Stirrer motor for penskymartens closed tester 115230v, 5060 hz. The automated pensky martens flash point analyzer represents a perfect union of nextgeneration technology with traditional robust quality. Astm d93, iso 2719, ip 34 cleveland opencup flash and fire point tester. May 16, 2016 model apm8 is an automated pensky martens closed cup flash point tester. Test method for flash point determinations of fuels, lubricating oils, liquids containing suspended solids and liquids that tend to form a surface film during testing. Automated penskymartens closed cup flash point tester apm8.
Features stepless variable heat control with reference. The flash point measures the tendency to form a flammable mixture with air while the fire point indicates the tendency of sustained burning. Foaming bath scavini petroleum testing apparatus for oil. K16225 stirrer motor, 115230v 5060hz slow speed gear motor rotates stirrer of penskymartens tester at 105rpm for procedure a and at 250rpm for procedure b.
Anumber in parentheses indicates the year of last reapproval. The automatic penskymartens closedcup tester measures the flash point at the lowest temperature at which the application of an ignition source causes the vapors of a sample to ignite. A fire extinguishing option is available with the pma 4. Automatic pensky martens closed cup flash point analyzer 110240v 5060hz koehler k7 the automated pensky martens flash point analyzer represents a perfect union of nextgeneration technology with traditional robust quality. Determination of a closed cup flash point of fuel, lubricating oils and other inflammable liquids.
Flash point determination instrumentation flash point testing equipment koehler instrument company inc is a manufacturer of pensky martens closed cup testers, pensky martens open cup testers, cleveland open cup tester, rapid flash tester closed cup, and autoignition apparatus. Get a realtime check of your isps performance and detect trends over time with data on. According to astm d9319, penskymartens test procedures can determine the flash point of petroleum products in the 40c to 370c range by either manual or automated closedcup apparatus, as well as determining the flash point of biodiesel in the 60c to 190c range by an automated closedcup apparatus. Penskymartens closed cup flash tester koehler instrument. Booklibrary manager ignitability and burning behaviour of materials. Electrically heated, with a two speed stirrer for astm d93ip 34, methods a and b. Includes adjustable support bracket and mounting rod. Automatic penskymartens flash point tester with integrated.
The flash point is the lowest temperature at which a liquid sample vaporizes to form an ignitable mixture with air. Tag closed cup method astm d56 abel closed cup iso 736, ip 170 excellent correlation to equilibrium and small scale methods en iso 36793680, astm d3828 ab, ip 523ip 524 fuel dilution flashpoint testing flash no flash methods fast screening methods available methods principle of. Includes shutter, flame exposure device, stirrer and thermometer ferrule. Apm00015 apm8 penskymartens closed cup flash point tester. Since 1966, tanaka has been delivering automated flash point testers for higher. Automatic penskymartens closedcup flash point tester. H2095 cleveland flash and fire point tester, natural gas. Basics of penskymartens closedcup flash point testing. Extensively used in shipping and safety regulations for detection of contamination by volatile and flammable materials in fuel oils and lubricating oils, and for characterization of hazardous. K14600 koehler instrument company summary of method. Koehler k902 k992 cleveland opencup flash point tester. What test methods are approved for determining if a liquid is. Slow speed gear motor rotates stirrer of penskymartens tester at 115rpm for procedure a and at 250rpm for procedure b.
The flash detector is a reliable and easytomaintain low mass thermocouple. Astm d93 standard test methods for flash point of petroleum products by penskymartens closed cup tester. Enhance your productivity with accessories for mac. Manual flash point by tag closed cup tester, fuels for. Thermocouple and ionization ring temperature range.
Via donne della resistenza, 26 28831 baveno verbania italy. Multifunctionhead onetwist with its quickcoupling widely avoids touching not surfaces. Pensky martens closed cup flash tester, gas heated. Professional automatic closedcup flash point tester.
K16203 description pensky marten flash point tester, manual version electrically heated, 115v 60hz. Berthold pensky developed the first closed cup flash point tester and set a milestone for the production of flash point testers based on. Standard test methods for flash point by penskymartens. Koehler k16010 cover assembly for penskymartens closed cup. Made as per gbt261 test methods for flash point of petroleum products closed cup methods. This tester determines flash points of a wide range of products by a closed cup method with slow speed stirring of the sample.
Standard test methods for flash point by penskymartens closed cup tester. Penskymartens closed cup flash tester conforms to astm d93 and related specifications choice of electric or gas. Speedtest for mac download speedtest for macos on the. Berthold pensky developed the first closed cup flash point tester and set a milestone for the production of flash point testers based on quality and precision. About 91% of these are testing equipment, 6% are other test instruments. Most of our asphalt test apparatus are astm compliant with standard asphalt evaluating protocols, for use in road paving quality control qc and research labs. The penskymartens flash point tester consists of a closedcup test arrangement that contains any vapors produced and essentially simulates the situation in which a potential source of ignition is accidentally introduced into a container. Apm7 automated penskymartens closed cup flash point tester. Qualtech products industry professional automatic flash point tester is a precision penskymartens closedcup flash point test instrument to determine the flash point of volatile samples. Koehler k16203 penskymartens closed cup flash point tester. The penskymartens closedcup flashpoint test is a test for the determination of the flash point of flammable liquids.